FINNER - S - High‑wall hydronic fan coil unit
These high wall-mounted fan coils are designed to meet and exceed the most demanding requirements in terms of efficiency, quiet operation, and design.
The backlit LED display, elegantly integrated into the front panel, ensures clear and immediate readability under any lighting conditions.
The slim and refined profile allows the unit to blend seamlessly into any environment.
The electronic control board ensures precise and reliable indoor comfort management.
Description
These high wall-mounted fan coils are designed to meet and exceed the most demanding requirements in terms of efficiency, low noise operation, and design.
The backlit LED display, elegantly integrated into the front panel, ensures clear and immediate readability in all lighting conditions.
The slim and refined profile fits seamlessly into any environment, while the electronic control board guarantees precise indoor comfort management.
The EC electronic motor ensures low energy consumption. By simply opening the front panel, the main components are easily accessible for quick and easy maintenance.
Main Technical Data
- Cooling capacity: from 1.46 kW to 6.57 kW
- Airflow rate: from 270 m³/h to 1250 m³/h
- Heating capacity: from 1.52 kW to 6.64 kW
(standard configuration with remote control / Wall Pad)
- High-efficiency EC brushless motor with automatic control via PID algorithm
- Available in 2-pipe and 4-pipe systems with high-efficiency ACHPS technology
- Operating modes:
- Cooling
- Heating
- Summer dehumidification
- Fan-only mode
- Integrated functions:
- Night mode
- Auto-Fan
- Daily timer
- Auto-Restart with memory of last settings in case of power failure
- Water temperature control with automatic unit shutdown in case of anomalies
- 3-way valve with by-pass and 230 Vac ON/OFF actuator (standard supply)
- Integrated open ModBus protocol:
- Connection up to 255 units
- PC control (optional)
- Emergency manual start and control via onboard button
- Inputs for:
- Presence sensor / window contact (ON/OFF)
- Economy mode
- Addressable master/slave control with error diagnostics (via Wall Pad)
- Expandable sub-network up to 32 units with centralized control
Standard Supply
Unit complete with:
- Full PCB electronic board for the control and management of both indoor and outdoor units (outdoor unit not supplied), with Modbus compatibility
- 3-way valve with by-pass and 230 Vac ON/OFF actuator
- Infrared remote control, also for managing motorized louvers
Technical features
Structure
Modern and aesthetically pleasing design with slim lines and rounded corners
White colour RAL 9010
Robust external structure in fire-retardant ABS
Air distribution
Optimal air distribution in all directions
Two motorized horizontal deflectors
Independent manual vertical deflectors
Fan
High-performance fan assembly designed to ensure maximum quietness across different airflow rates
Tangential fans
Single-phase permanent capacitor motors
Heat exchanger
Latest-generation technology
Large heat exchange surface
High-efficiency aluminium fins
Air vent valve
Water drain valve
Filters
Easily accessible by lifting the front panel
No tools required for maintenance or removal
Washable and reusable
Flexible pipes
Two synthetic elastomer hoses with external steel braid
Quick connectors for system connection without welding
Unit control
Standard infrared remote control supplied
Wall-mounted Wall Pad (optional) with:
- Weekly programming
- Integrated clock
- Master/slave line control (global or individual units)
- Error diagnostics
User thermostat (with optional Mini PCB board)
Optional Wi-Fi thermostat compatible with Mini PCB board
Available documents
FAQ
Il Finner-S è progettato per applicazioni residenziali e terziarie leggere, come hotel, uffici e strutture ricettive, dove è richiesta installazione a parete alta. È particolarmente adatto in ambienti con vincoli architettonici o spazi limitati, dove non è possibile utilizzare terminali a pavimento o controsoffitto.
Si tratta di un ventilconvettore idronico che utilizza acqua calda o refrigerata proveniente da pompe di calore o chiller. L’installazione a parete alta favorisce una diffusione dell’aria più uniforme, migliorando la miscelazione e riducendo fenomeni di stratificazione, soprattutto in modalità raffrescamento.
Il Finner-S è progettato per garantire basse emissioni sonore e una distribuzione omogenea dell’aria, aspetti fondamentali in ambienti come camere d’hotel o uffici. La regolazione della velocità del ventilatore consente di adattare la resa termica alle condizioni di carico, mantenendo un buon equilibrio tra comfort e consumi.
L’installazione a parete alta richiede una corretta valutazione della posizione per evitare correnti dirette sugli occupanti. È importante prevedere adeguati scarichi condensa in raffrescamento e garantire l’accessibilità per la manutenzione. L’integrazione con sistemi di regolazione ambiente (termostati o BMS) è fondamentale per ottimizzare il funzionamento.
Rispetto ai ventilconvettori a pavimento, il Finner-S libera spazio utile e migliora l’integrazione architettonica. Rispetto ai sistemi canalizzati, riduce complessità e costi installativi. Inoltre, consente una regolazione per singolo ambiente, aumentando la flessibilità gestionale dell’impianto.
È una soluzione efficace in retrofit o riqualificazioni dove non è possibile intervenire con reti canalizzate o sistemi radianti. Permette di gestire facilmente sia riscaldamento che raffrescamento con un unico terminale, migliorando la flessibilità impiantistica e garantendo comfort anche in ambienti con carichi variabili.